SERIAL NUMBER (located on back of product):
PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 04/11/2014 M620R-B
Phone: 800-669-1303 or 801-561-0303
Fax: 801-255-2312
e-mail: treborservice@idexcorp.com
MAGNUM 620R PUMP
Operation / Maintenance
Manual
Page view 0
1 2 3 4 5 6 ... 27 28

Summary of Contents

Page 1 - MAGNUM 620R PUMP

SERIAL NUMBER (located on back of product): PATENTS: U.S. 09642426, U.S. 06106246, U.S. 05971402, U.S. 05370507 04/11/2014– M620R-B Phone: 800-669

Page 2 - CONTENTS

PAGE 10 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 3 START-UP  Pump air supply pressure must be regulated. (See Figure 3-3: Pressure vs. Fl

Page 3 - 1 INSTALLATION

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 11 01020304050607080900 2 4 6 8 10 12Flow (gpm)Discharge Pressure (psi)No Spring Load Require

Page 4

PAGE 12 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 468101230 40 50 60 70 80Supply Pressure (psig)Flow (gpm)Medium LoadHigh LoadNo Load Figure 3

Page 5 - 1.3 CHECK MUFFLER OPERATION

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 13 4 MAINTENANCE Trebor pump maintenance can be divided into two categories: air system main

Page 6

PAGE 14 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL MAGNUM 620R Maintenance Schedule Install 30 Days 3 Months 6 Months 9 Months 12 Months 15 Mo

Page 7 - 1.4 REMOTE EXHAUST HOOK-UP

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 15 4.1.a Preventive Maintenance Record Company Name: _______________________________________

Page 8 - 2 OPTIONS

PAGE 16 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 4.2 RECOMMENDED SPARE PARTS KR620R-00-A Spares Rebuild Kit, which includes: Part No Qty Des

Page 9 - Figure 2-2

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 17 4.4 PARTS ILLUSTRATION

Page 10 - 3 START-UP

PAGE 18 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 4.5 PARTS LIST ILL NO PART NO QTY DESCRIPTION PM YEAR # MATERIAL 1 AW021 1 Detent Cap PP 2

Page 11 - Medium Load*

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 19  Immerse or flush the pump assembly using DI water and a neutralizing agent.  Install

Page 12 - High Load

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL CONTENTS CONTENTS 1 INSTALLATION ...

Page 13 - 4 MAINTENANCE

PAGE 20 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL CAUTION: Following disassembly, parts should be thoroughly washed and free from chemical re

Page 14

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 21  Tilt the detent ring (item 3) over one of the legs, and align the groove on the inside

Page 15

PAGE 22 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL ATTENTION: Threads should be snug. Do not over tighten.  Thread muffler assembly into hea

Page 16 - 4.2 RECOMMENDED SPARE PARTS

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 23  Install two shaft seals in shaft bore groove with slits 180 apart.  Thread shaft int

Page 17 - 4.4 PARTS ILLUSTRATION

PAGE 24 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL Figure 4-7  Install fittings and transfer tubes. See Figure 4-8.  Reconnect both air s

Page 18 - 4.7 DISASSEMBLY

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 25 4.9 TESTING Performance Test  With the air supply at 0 psi open the air supply valve 

Page 19

PAGE 26 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 5 TROUBLESHOOTING Pump Will Not Start, Fails to Operate Cause: Solution:  Insufficient a

Page 20 - 4.8 ASSEMBLY

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 27 6 WARRANTY MAGNUM 620 PUMP TREBOR International, Inc. warrants to the purchaser of new

Page 21

PAGE 28 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 7 CONTACT INFORMATION 7.1 GENERAL CONTACT INFORMATION Web: www.treborintl.com Phone

Page 22 - 4.8.b Pump Assembly

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 3 1 INSTALLATION 1.1 UNPACKING After unpacking, the pump should be checked for any damage t

Page 23 - 4.8.c Final Assembly

PAGE 4 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL Figure 1-1: Dimensional Views ATTENTION: The pump should be operated with clean, dry air or

Page 24

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 5 1.3 CHECK MUFFLER OPERATION 1.3.a Purpose NOTE: The check muffler is not designed to cont

Page 25 - 4.9 TESTING

PAGE 6 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL  If none of the aforementioned conditions exist when operating the pump, then the final set

Page 26 - 5 TROUBLESHOOTING

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 7 1.4 REMOTE EXHAUST HOOK-UP Some installations may benefit from remotely exhausting air fr

Page 27 - 6 WARRANTY

PAGE 8 MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL 2 OPTIONS 2.1 FLUID PORT CONNECTION OPTIONS NOTE 1: Use O-ring to seal stainless steel or o

Page 28 - 7 CONTACT INFORMATION

MAGNUM 620R PUMP OPERATION / MAINTENANCE MANUAL PAGE 9 Figure 2-2 NOTE: See Surge Suppressor Operation Manual for detailed installation instructi